Xevo TQD (Tandem/triple quadrupole mass spectrometer) from Waters Corporation


Description

The single vendor solution for routine quantitative UPLC-MS/MS applications, providing maximum accessibility to the sensitivity, selectivity and robustness needed to ensure maximum productivity with minimum effort.

  • Maximum uptime through unparalleled robustness.
  • Accelerated method development for sensitive and robust methods.
  • Reduces complexity, increases ease of use, and ensures the correct result every time.
  • Maximize throughput with no compromise on quality.
  • The widest range of ionization capabilities today, future-proofing for the innovations of tomorrow.

Maximum uptime through unparalleled robustness

Rapid round the clock analysis requires a reliable, robust system, capable of delivering the same result everytime.

Understanding sample complexity

Some challenges for quantitative methods are:

  • Calculating compound concentrations in addition to the detection of unexpected contaminants.
  • Characterization of the background matrix for every sample, increasing data quality.
  • Detection of analytes that are not in a targeted multiple reaction monitoring (MRM) screening method.
  • Improving method development by discovering more matrix components.

 These challenges may be overcome by using RADAR which is the ability to obtain full scan (MS) and MRM (MS/MS) data simultaneously.

Product Ion Confirmation scanning (PICS) allows you to have full confidence in your results. Activated by a single check box in the method editor, PICS automatically triggers a product ion scan when a peak is detected by MRM.

Ensures the correct result every time

Prepare – IntelliStart™ and Quanpedia™ enable rapid, automated set-up and checking of the system and all of its methods, coupled with automatically scheduling MRM transitions to maximize performance.

Analyze – During analysis, QCMonitor will actively monitor the data in real time, taking action if any user specified tolerances are exceeded.

Interpret – TargetLynx provides automated quantification and reporting, with automated highly visible flags reducing the possibility for error.

Decide –TrendPlot enables you to visualize results over many days, weeks or months; providing valuable information on data trends and long term system performance.

Maximum uptime through unparalleled robustness

Rapid round the clock analysis requires a reliable, robust system, capable of delivering the same result every time.

Understanding sample complexity

Some challenges for quantitative methods are:

  • Calculating compound concentrations in addition to the detection of unexpected contaminants.
  • Characterization of the background matrix for every sample, increasing data quality.
  • Detection of analytes that are not in a targeted multiple reaction monitoring (MRM) screening method.
  • Improving method development by discovering more matrix components.

These challenges may be overcome by using RADAR which is the ability to obtain full scan (MS) and MRM (MS/MS) data simultaneously.

Product Ion Confirmation scanning (PICS) allows you to have full confidence in your results. Activated by a single check box in the method editor, PICS automatically triggers a product ion scan when a peak is detected by MRM.

Ensures the correct result every time

Prepare – IntelliStart™ and Quanpedia™ enable rapid, automated set-up and checking of the system and all of its methods, coupled with automatically scheduling MRM transitions to maximize performance.

Analyze – During analysis, QCMonitor will actively monitor the data in real time, taking action if any user specified tolerances are exceeded.

Interpret – TargetLynx provides automated quantification and reporting, with automated highly visible flags reducing the possibility for error.

Decide –TrendPlot enables you to visualize results over many days, weeks or months; providing valuable information on data trends and long term system performance.

Maximize throughput with no compromise on quality

Accurate quantitation of the narrow peak widths typical of UPLC® (2 to 3 s) demands fast acquisition speeds to ensure data quality targets are achieved. The T-Wave collision cell ensures that the UPLC chromatographic speed and resolution benefits can be fully exploited, whether you are analyzing one compound, or hundreds of compounds, per method.



Waters Corporation Contact Information

Waters Corporation

34 Maple St.
Milford, MA 01757

800-252-4752

Waters Corporation Web Site

Login Form

Forget your password?

Create Login

 
 
 
 

May we keep you up to date with other communications?

 

Concerned about your privacy?

Refine Your Search

Search in: